Delta Electronics — P0.xxx Monitoring parameters

ASDA-B3 Parameters 8 Settings: Before using this function, set the digital output function to [0x2E] (third set of general range comparison) and the monitoring items of P0.019. When the monitoring item value of P0.011 is within the range set in P0.058 and P0.059, and after the filter time set in P0.053.Z has elapsed, this digital output is on. Settings: Refer to the description of P0.058. Settings: Before using this function, set the digital output function to [0x2F] (fourth set of general range comparison) and the monitoring items of P0.020.

When the monitoring item value of P0.012 is within the range set in P0.060 and P0.061, and after the filter time set in P0.053.U has elapsed, this digital output is on. Settings: Refer to the description of P0.060. 8-27 Address: 0075H P0.058 General range compare digital output - third lower limit 0076H Default: 0 Control mode: All Unit: - Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit Address: 0077H P0.059 General range compare digital output - third upper limit 0078H Default: 0 Control mode: All Unit: - Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit Address:

0079H P0.060 General range compare digital output - fourth lower limit 007AH Default: 0 Control mode: All Unit: - Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit Address: 007BH P0.061 General range compare digital output - fourth upper limit 007CH Default: 0 Control mode: All Unit: - Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit P0.062 Reserved