Parameters ASDA-B3 8 Settings: Before using this function, set the digital output function to [0x2C] (first set of general range comparison) and the monitoring items of P0.017. When the monitoring item value of P0.009 is within the range set in P0.054 and P0.055, and after the filter time set in P0.053.X has elapsed, this digital output is on. Settings: Refer to the description of P0.054. Settings: Before using this function, set the digital output function to [0x2D] (second set of general range comparison) and the monitoring items of P0.018.
When the monitoring item value of P0.010 is within the range set in P0.056 and P0.057, and after the filter time set in P0.053.Y has elapsed, this digital output is on. Settings: Refer to the description of P0.056. 8-26 Address: 006CH P0.054 General range compare digital output - first lower limit 006DH Default: 0 Control mode: Unit: - Setting range: Format: DEC Data size: Address: 006EH P0.055 General range compare digital output - first upper limit 006FH Default: 0 Control mode: All Unit: - Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit Address: 0071H P0.056 General range compare digital output - second lower limit 0072H Default: 0 Control mode: All Unit:
- Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit Address: 0073H P0.057 General range compare digital output - second upper limit 0074H Default: 0 Control mode: All Unit: - Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit