ASDA-B3 Parameters 8 Settings: When you set P2.070 [Bit 1] to 1 for reading the pulse number, this parameter indicates the pulse number of the encoder which refers to the motor’s absolute position within a single turn. When you set P2.070 [Bit 1] to 0 for reading the PUU number, this parameter indicates the motor’s absolute position in PUU. Settings: Y Z U X Note: the minimum filter time is 1 ms (set value 0 = 1 ms; 1 = 2 ms; 2 = 3 ms; ...; F = 16 ms). Example of the first filter: P0.055 P0.054 DO: 0x2C 8-25 Encoder absolute position - pulse number or PUU within Address: 0068H P0.052★■ single turn 0069H Default: 0 Control mode: Unit: pulse or PUU Setting range: Format: DEC Data size:
Address: 006AH P0.053 General range compare DO output - filter time 006BH Default: 0x0000 Control mode: All Unit: - Setting range: 0x0000 - 0xFFFF Format: HEX Data size: 16-bit X First filter time Z Third filter time Y Second filter time U Fourth filter time P0.009 monitoring item value On Off P0.053.X filter time P0.053.X filter time