Delta Electronics — P0.xxx Monitoring parameters

Parameters ASDA-B3 Reserved  X: command processing Reserved 8 0: N/A 1: update the encoder data in P0.050 - P0.052. 2: update the values in P0.050 - P0.052 and clear the position error. When this command takes effect, the motor's current position is set to the terminal point of the Position command. Settings: Bit Bit Settings: When you set P2.070 [Bit 1] to 1 for reading the pulse number, this parameter indicates the number of turns of the motor (absolute position). When you set P2.070 [Bit 1] to 0 for reading the PUU number, this parameter becomes invalid and the panel displays 0. 8-24 X Command processing Z Y Reserved U Address:

0064H P0.050★■ Absolute coordinate system status 0065H Default: 0x0000 Control mode: All Unit: - Setting range: 0x0000 - 0x001F Format: HEX Data size: 16-bit 7 6 5 4 3 2 1 0 15 14 13 12 11 10 9 8 Bit Function Description Bit 0 Absolute position status 0: normal. 1: lost. Bit 1 Battery voltage status 0: normal. 1: undervoltage. Bit 2 Status for absolute number of turns 0: normal. 1: overflows. Bit 3 PUU status 0: normal. 1: overflows. Bit 4 Absolute coordinate status 0: established. 1: not yet established. Bit 5 - Bit 15 Reserved - Address: 0066H P0.051★■ Encoder absolute position - multiple turns 0067H Default: 0 Control mode: All Unit: rev Setting range: -32768 to +32767 Format:

DEC Data size: 16-bit