Delta Electronics — P1.xxx Basic parameters

ASDA-B3 Parameters P1.xxx Basic parameters 8 Settings: Y Z U X  X: pulse type 0: AB phase pulse (4x) 1: clockwise and counterclockwise pulse 2: pulse + symbol  Z: logic type 0: positive logic 1: negative logic Digital circuits use 0 and 1 to represent the high and low voltage levels. In positive logic, 1 represents high voltage and 0 represents low voltage. In negative logic, 1 represents low voltage and 0 represents high voltage. Example: Positive logic Negative logic 8-29 Address: 0100H 0101H P1.000▲ External pulse input type Default: 0x1042 Control mode: PT Unit: - Setting range: 0x0000 - 0x11F2 Format: HEX Data size:

16-bit X Pulse type Z Logic type Y Filter width U Filter width Logic Pulse Pulse input type type Forward Reverse Pulse phase lead (43) PULSE TH (41) (39) SIGN T1 T1 T1 T1 T1 (37) Pulse phase lag (43) PULSE TH (41) (39) SIGN T1 T1 T1 T1 T1 T1 (37) X = 0 Z = 0 (43) PULSE TH (41) T2 T2 T2 T2 T2 T2 T3 T2 T2 T2 T2 T2 T2 (39) SIGN TH (37) X = 1 T1 T1 T1 (43) PULSE (41) T2 T2 (39) SIGN (37)