ASDA-B3 Parameters 8 Settings: Internal Speed command 3: third internal Speed command. Internal speed limit 3: third internal speed limit. Example of internal speed limit: Settings: Internal Torque command 1: first internal Torque command. Internal torque limit 1: first internal torque limit. Example of internal torque limit: 8-37 Address: 0116H P1.011 Internal Speed command 3 / internal speed limit 3 0117H 3000 Default: Control mode: Unit: 0.1 rpm Setting range: Format: DEC Data size: Example: Speed limit value of P1.011 Valid speed range Speed limit in forward direction Speed limit in reverse direction 1000 -100 to 100 rpm 100 rpm -100 rpm -1000 Address:
0118H P1.012 Internal Torque command 1 / internal torque limit 1 0119H 100 T / Tz: internal Torque command 1 PT / PR / S / Sz: internal torque limit 1 Default: Control mode: Unit: % Setting range: -500 to +500 Format: DEC Data size: 16-bit Internal Torque command: 30 = 30% Internal torque limit: positive and negative values are identical. Refer to the following descriptions. Example: Torque limit value of P1.012 Valid torque range Torque limit in forward direction Torque limit in reverse direction 30 -30 to 30% 30% -30% -30