Delta Electronics — P1.xxx Basic parameters

Parameters ASDA-B3 8 Settings: Internal Torque command 2: second internal Torque command. Internal torque limit 2: second internal torque limit. Example of internal torque limit: Settings: Internal Torque command 3: third internal Torque command. Internal torque limit 3: third internal torque limit. Example of internal torque limit: 8-38 Address: 011AH P1.013 Internal Torque command 2 / internal torque limit 2 011BH 100 T / Tz: internal Torque command 2 PT / PR / S / Sz: internal torque limit 2 Default: Control mode: Unit: % Setting range: -500 to +500 Format: DEC Data size: 16-bit Internal Torque command: 30 = 30% Internal torque limit: positive and negative values are identical.

Refer to the following descriptions. Example: Torque limit value of P1.013 Valid torque range Torque limit in forward direction Torque limit in reverse direction 30 -30 to 30% 30% -30% -30 Address: 011CH P1.014 Internal Torque command 3 / internal torque limit 3 011DH 100 T / Tz: internal Torque command 3 PT / PR / S / Sz: internal torque limit 3 Default: Control mode: Unit: % Setting range: -500 to +500 Format: DEC Data size: 16-bit Internal Torque command: 30 = 30% Internal torque limit: positive and negative values are identical. Refer to the following descriptions. Example:

Torque limit value of P1.014 Valid torque range Torque limit in forward direction Torque limit in reverse direction 30 -30 to 30% 30% -30% -30 P 1.015 - Reserved P 1.018