Delta Electronics — P2.xxx Extension parameters

Parameters ASDA-B3 8 Settings: Refer to the description of P2.060. Settings: Refer to the description of P2.060. Settings: Bit Bit 8-82 Address: 027AH P2.061 E-Gear ratio (numerator) (N3) 027BH Default: 16777216 Control mode: PT Unit: pulse Setting range: 1 to (229-1) Format: DEC Data size: 32-bit Address: 027CH P2.062 E-Gear ratio (numerator) (N4) 027DH Default: 16777216 Control mode: PT Unit: pulse Setting range: 1 to (229-1) Format: DEC Data size: 32-bit P 2.063 - Reserved P2.064 Address: 0282H P2.065 Special bit register 0283H Default: 0x0104 Control mode: PT / PR / S / Sz Unit: - Setting range: 0 - 0xFFFF Format: HEX Data size:

- 7 6 5 4 3 2 1 0 15 14 13 12 11 10 9 8 Bit Function Description Bit 0 - Bit 2 Reserved - Bit 3 Methods for regenerative energy consumption 0: determined by the servo’s internal algorithm. 1: determined by the DC Bus voltage. Bit 4 - Bit 5 Reserved - Bit 6 Pulse error (pulse frequency is too high) protection function in PT mode 0: enable the function. 1: disable the function. Bit 7 Reserved - Bit 8 U, V, W wiring error detection function 0: disable the function. 1: enable the function. Bit 9 U, V, W disconnection detection function 0: disable the function. 1: enable the function. Bit 10 ZCLAMP function selection The ZCLAMP function is enabled when all the following conditions are met.

Condition 1: Speed mode Condition 2: DI.ZCLAMP is on Condition 3: motor speed is slower than the value of P1.038