Delta Electronics — P2.xxx Extension parameters

ASDA-B3 Parameters 8 Settings: Sets the scale of the indexing coordinates, indexing command position, and indexing feedback position. If the value is too small, it may cause errors in the indexing coordinates. The ranges of values for P2.052 are: P2.052 > 1.05 x Maximum motor speed (rpm) x 16777216 60000 x P1.045 P1.044 P2.052 > 279.62 x Maximum motor speed (rpm) x P1.045 P1.044 Settings: Increase the position control integral compensation to reduce the position steady-state errors. If the value is too high, it may cause position overshoot and noise. Settings: The numerator of the E-Gear ratio can be selected with DI.GNUM0 and DI.GNUM1 (refer to Table 8.1).

If both DI.GNUM0 and DI.GNUM1 are not defined, P1.044 is the default numerator of the E-Gear ratio. Switch DI.GNUM0 and DI.GNUM1 only when the servo is stopped in order to avoid mechanical vibration. GNUM0, GNUM1 1 st numerator (P1.044) 2 nd numerator (P2.060) 3 rd numerator (P2.061) 4 th numerator (P2.062) Position command moving filter Pulse (P1.068) ---------------------------- Denominator (P1.045) Smooth filter (P1.008) Pulse Feedback pulse Error 8-81 Address: 0268H P2.052▲ Indexing coordinates scale 0269H Default: 1000000000 Control mode: All Unit: PUU Setting range: 0 - 1000000000 Format: DEC Data size: 32-bit Address: 026AH P2.053 Position integral compensation 026BH Default: