Delta Electronics — P2.xxx Extension parameters

Parameters ASDA-B3 8  Bit 10 = 1 and command source is the internal register. ZCLAMP function uses the register Speed command with acceleration or deceleration to determine if this function should be enabled. When ZCLAMP conditions are met, the motor speed is set to 0 rpm. 8-84 Bit Function Description Bit 11 Pulse inhibit function switch 0: disable PL / NL pulse inhibit function. In PT mode, the servo drive receives pulse position commands for both positive- and negative-direction operations whether the motor reaches the NL or PL. 1: enable PL / NL pulse inhibit function.

In PT mode, if the motor reaches the PL, the servo drive receives pulse position commands for negative-direction opertaion and stops receiving pulse position commands for positive-direction operataion. In PT mode, if the motor reaches the NL, the servo drive receives pulse position commands for positive-direction operation and stops receiving pulse position commands for negative-direction operation. Bit 12 Leak phase detection function 0: enable the leak phase (AL022) detection function. 1: disable the leak phase (AL022) detection function. Bit 13 Encoder output error detection function 0: enable encoder output error (AL018) detection function. 1:

disable encoder output error (AL018) detection function. Bit 14 Reserved - Bit 15 Friction compensation mode selection 0: the compensation value remains unchanged when motor speed is slower than the value of P1.038. 1: the compensation value reduces to 0 when motor speed is slower than the value of P1.038.