ASDA-B3 Parameters P3.xxx Communication parameters 8 Settings: YX Z U When using RS-485 to communicate, one servo drive can set only one address. Setting more than one addresses causes abnormal communications. This address represents the absolute address of the servo drive in the communication network. It is applicable to RS-485, CANopen, DMCNET, and EtherCAT. When the communication address of MODBUS is 0xFF, the servo drive automatically receives and replies the data regardless of the address, but P3.000 cannot be set to 0xFF. Settings: Y Z U X X: RS-485 transmission speed 0: 4800 bps 1: 9600 bps 2: 19200 bps 3: 38400 bps 4: 57600 bps 5: 115200 bps Z:
CANopen / DMCNET transmission speed 0: 125 Kbps 1: 250 Kbps 2: 500 Kbps 3: 750 Kbps 4: 1.0 Mbps - 8-93 Address: 0300H P3.000● Address 0301H Default: 0x007F Control mode: All - 0x0001 - 0x007F 0x0001 - 0xFFFF (B3-E) Unit: Setting range: Format: HEX Data size: 16-bit UZYX Communication address setting Address: 0302H P3.001● Transmission speed 0303H 0x0203 (B3-L, M, E) 0x3203 (B3-F) All Default: Control mode: - 0x0000 - 0x0405 (B3-L, M, E) 0x0000 - 0xF405 (B3-F) Unit: Setting range: Format: HEX Data size: 16-bit X RS-485 transmission speed Z CANopen / DMCNET transmission speed Y Reserved U DMCNET motion card