Delta Electronics — P3.xxx Communication parameters

Parameters ASDA-B3  U: DMCNET motion card 0: use Delta’s controller, such as PLC or HMI 8 3: use Delta’s motion card Note: 1. The communication speed of USB is set at 1.0 Mbps and cannot be changed. 2. If this parameter is set through CANopen, only Z can be set and the others remain unchanged. 3. After the Z value is set, cycle the power to take effect. Settings: Definition of each value: Settings: 0: display warning and let motor continue operating. 1: display warning and let motor decelerate to a stop. Deceleration time is set in P5.003.B. Settings: If the value is not 0, communication timeout is enabled immediately. 8-94 Address: 0304H P3.002 Communication protocol 0305H Default:

0x0006 Control mode: All Unit: - Setting range: 0x0000 - 0x0008 Format: HEX Data size: 16-bit 0: 7, N, 2 (MODBUS, ASCII) 1: 7, E, 1 (MODBUS, ASCII) 2: 7, O, 1 (MODBUS, ASCII) 3: 8, N, 2 (MODBUS, ASCII) 4: 8, E, 1 (MODBUS, ASCII) 5: 8, O, 1 (MODBUS, ASCII) 6: 8, N, 2 (MODBUS, RTU) 7: 8, E, 1 (MODBUS, RTU) 8: 8, O, 1 (MODBUS, RTU) Address: 0306H P3.003 Modbus communication error handling 0307H Default: 0x0000 Control mode: All Unit: - Setting range: 0x0000 - 0x0001 Format: HEX Data size: 16-bit Address: 0308H P3.004 Communication timeout 0309H Default: 0 Control mode: All Unit: sec Setting range: 0 - 20 (0: disable this function) Format: DEC Data size: 16-bit P 3.005 Reserved