ASDA-B3 Parameters 8 Settings: Source of the DI that controls the switch. Each bit of this parameter determines one input source of DI signal: Bit 0 - Bit 8 correspond to DI1 - DI9; Bit 9 - Bit 12 correspond to DI10 - DI13. The setting for each bit is as follows: 0: DI status is controlled by the external terminal block. 1: DI status is controlled by P4.007. For more information on DI functional planning, please see: DI1 - DI8: P2.010 - P2.017 DI9 - DI13: P2.036 - P2.040 Settings: Delay the time of RS-485 communication response from servo drive to controller. Settings: The synchronous setting is divided into U, Z, Y, and X (hexadecimal): The slave synchronizes with the master via SYNC.
The definition is as follows: X: reserved. Y: set the size of deadband (unit: μsec). If the deviation between the SYNC arrival time and the target value does not exceed the deadband, a correction is not needed. Z: target value of SYNC arrival time. The standard value is 500 μsec, but you need to take the 8-95 Address: 030CH P3.006■ Digital input (DI) control switch 030DH Default: 0x0000 Control mode: All Unit: - Setting range: 0x0000 - 0x1FFF Format: HEX Data size: 16-bit Address: 030EH P3.007 Modbus communication response delay time 030FH Default: 0 Control mode: All Unit: 0.5 ms Setting range: 0 - 1000 Format: DEC Data size: 16-bit P 3.008 Reserved Address:
0312H P3.009 Communication synchronization 0313H Default: 0x5055 Control mode: CANopen Unit: - Setting range: Shown as follows Format: HEX Data size: 16-bit Digit U Z Y X Function Range of synchronous error Target value Deadband - Range 1 - 9 0 - 9 0 - F -