Parameters ASDA-B3 Related variables for Z settings: 8 Methods to write parameters to EEPROM (even when the power is off): SDO: parameters are stored in EEPROM when written. PDO: refer to the setting of P3.011.X. (X = 1: when you write parameters through PDOs, parameters are stored in EEPROM; X = 0: when you write parameters through PDOs, parameters are not stored in EEPROM.) Note: when using OD 1010 Store Parameter, the servo drive stores the CANopen OD in non-volatile memory. If P3.012.Z = 0, then the initial values are the corresponding CANopen OD vaues specified in the CANopen Stardard document. If P3.012.Z = 1, then the initial values are the values listed in the above table. Settings:
Z: AL185 communication disconnection detection setting 0: disconnection detection starts after EtherCAT communication enters OP state. 8-98 Variables during initialization P3.012.Z = 0 P3.012.Z = 1 Note P1.032 0x0010 EEPROM - P2.035 50331648 EEPROM - P1.047 100 EEPROM - P1.049 0 EEPROM - P1.038 100 EEPROM - P6.001 0 EEPROM - Acc (P1.034) 200 EEPROM Used in PV and PP modes Dec (P1.034) 200 EEPROM Used in PV and PP modes Torque slope (P1.034) 200 EEPROM Used in PT mode P1.044 1 EEPROM - P1.045 1 EEPROM - P1.055 Depending on the motor specifications EEPROM - P5.008 2147483647 EEPROM - P5.009 -2147483648 EEPROM - P 3.013 - Reserved P3.017 Address:
0324H P3.018 EtherCAT special function switch 0325H Default: 0x00002000 Control mode: EtherCAT Unit: - Setting range: 0x00000000 - 0x00112211 Format: HEX Data size: 32-bit High bit Low bit D C B A U Z Y X A Reserved X Reserved B Reserved Y Reserved C Reserved Z AL185 communication disconnection detection setting D Reserved U Reserved