Delta Electronics — P3.xxx Communication parameters

ASDA-B3 Parameters Communication setting is divided into X, Y, Z, and U (hexadecimal): 8  X: parameter is stored in EEPROM or not 0: parameters are not stored in EEPROM. 1: when you write parameters through CANopen / DMCNET PDOs, parameters are stored in EEPROM. Note: if you set X to 1 and continuously write parameters through DMCNET PDO, it shortens the lifetime of the EEPROM. Settings: Y Z U X X: reserved. Y: reserved. Z: P parameters are overwritten by the CANopen / DMCNET / EtherCAT parameters. Z = 0: when you cycle the power on the servo drive or reset the communication, P parameters in the Z = 1:

when you cycle the power on the servo drive or reset the communication, P parameters in the following table load the values in CANopen / DMCNET / EtherCAT mode. following table retain the same settings and do not load the values in CANopen / DMCNET / EtherCAT mode. 8-97 Digit U Z Y X - - - - - - Address: 0318H P3.012 Fieldbus support setting 0319H Default: 0x0000 Control mode: CANopen / DMCNET / EtherCAT Unit: - Setting range: 0x0000 - 0x0111 Format: HEX Data size: 16-bit Digit U Z Y X Function Reserved Load in CANopen / DMCNET / EtherCAT values Reserved Reserved Range - 0 - 1 - -