Delta Electronics — P5.xxx Motion control parameters

ASDA-B3 Parameters P5.xxx Motion control parameters 8 Settings: The low bit is the subversion of the firmware. Settings: The parameter setting is divided into D, C, B, A, W, Z, Y, and X (hexadecimal), including: 1. Deceleration time when the auto-protection function is enabled: OVF (DO: 0x12, Position command / feedback overflows), CTO (communication timeout, AL020), SPL, SNL, PL, and NL. 2. Deceleration time for stop command: STP Use 0 - F to index the deceleration time of P5.020 - P5.035. For example: if you set X to A, then the deceleration time of PL is determined by P5.030. Settings: Y Z U X 8-107 Address: 0500H P5.000★■ Firmware subversion 0501H Default: Factory setting Control mode:

All Unit: - Setting range: - Format: DEC Data size: 32-bit P5 .001 - Reserved P5.002 Address: 0506H P5.003 Deceleration time for auto-protection 0507H Default: 0xEEEFEEFF Control mode: PR / S / T Unit: - Setting range: 0x00000000 - 0xFFFFFFFF Format: HEX Data size: 32-bit Digit D C B A W Z Y X Function STP PFQS CTO OVF SNL SPL NL PL Range 0 - F 0 - F 0 - F 0 - F 0 - F 0 - F 0 - F 0 - F Address: 0508H P5.004 Homing methods 0509H Default: 0x0000 Control mode: PR Unit: - Setting range: 0x0000 - 0x012A Format: HEX Data size: 16-bit X Homing method Z Limit setting Y Z pulse setting U Reserved