Delta Electronics — P5.xxx Motion control parameters

ASDA-B3 Parameters 8 Settings: Refer to P5.020 for the acceleration / deceleration time in PR mode. Settings: Refer to P5.020 for the acceleration / deceleration time in PR mode. Settings: Refer to P5.020 for the acceleration / deceleration time in PR mode. Settings: Refer to P5.020 for the acceleration / deceleration time in PR mode. Settings: Refer to P5.020 for the acceleration / deceleration time in PR mode. 8-113 Address: 052CH P5.022 Acceleration / deceleration time (Number #2) 052DH Default: 500 Control mode: PR Unit: ms Setting range: 1 to 65500 Format: DEC Data size: 16-bit Address: 052EH P5.023 Acceleration / deceleration time (Number #3) 052FH Default: 600 Control mode: PR Unit:

ms Setting range: 1 to 65500 Format: DEC Data size: 16-bit Address: 0530H P5.024 Acceleration / deceleration time (Number #4) 0531H Default: 800 Control mode: PR Unit: ms Setting range: 1 to 65500 Format: DEC Data size: 16-bit Address: 0532H P5.025 Acceleration / deceleration time (Number #5) 0533H Default: 900 Control mode: PR Unit: ms Setting range: 1 to 65500 Format: DEC Data size: 16-bit Address: 0534H P5.026 Acceleration / deceleration time (Number #6) 0535H Default: 1000 Control mode: PR Unit: ms Setting range: 1 to 65500 Format: DEC Data size: 16-bit