Delta Electronics — P5.xxx Motion control parameters

Parameters ASDA-B3 8 Settings: Read: feedback position of the encoder, which is the monitoring variable 000(00h) + offset value. Write: write any value to the parameter, and it neither changes the monitoring variable 000(00h) nor affects the positioning coordinate system. It is only for observation when you adjust the offset value. Settings: Pulse count from the pulse command. Settings: The duration of acceleration and deceleration in PR mode, which is the length of time to accelerate from 0 to 3,000 rpm. Settings: Refer to P5.020 for the acceleration / deceleration time in PR mode. 8-112 Address: 0520H P5.016■ Axis position - motor encoder 0521H Default: 0 Control mode: All Unit:

PUU Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit P 5.017 Reserved Address: 0524H P5.018 Axis position - pulse command 0525H Default: 0 Control mode: All Unit: pulse Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit P 5.019 Reserved Address: 0528H P5.020 Acceleration / deceleration time (Number #0) 0529H Default: 200 Control mode: PR Unit: ms Setting range: 1 to 65500 Format: DEC Data size: 16-bit Address: 052AH P5.021 Acceleration / deceleration time (Number #1) 052BH Default: 300 Control mode: PR Unit: ms Setting range: 1 to 65500 Format: DEC Data size: 16-bit