Delta Electronics — P5.xxx Motion control parameters

ASDA-B3 Parameters 8 Settings: Window #1: when you read the parameter with the panel, the value set in P5.011 does not add 1, but reading or writing by other methods adds 1. Refer to Section 7.2.1 Data array for detailed instructions. Settings: Window #2: when you read the parameter with the panel or read and write the parameter through communication, the value set inP5.011 adds 1, but the panel is write-protected. Refer to Section 7.2.1 Data array for detailed instructions. Settings: This parameter allows you to write data to the target continuously through communication. Y Z U X  X: PATH#1 volatile setting 0: non-volatile 1: volatile  Y: PATH#2 volatile setting 0: non-volatile 1:

volatile 8-111 Address: 0518H P5.012■ Data array - window #1 for reading and writing 0519H Default: 0 Control mode: All Unit: - Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit Address: 051AH P5.013■ Data array - window #2 for reading and writing 051BH Default: 0 Control mode: All Unit: - Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit P 5.014 Reserved Address: 051EH P5.015■ PATH#1 - PATH#2 volatile setting 051FH Default: 0x0000 Control mode: PR Unit: - Setting range: 0x0000 - 0x0011 Format: HEX Data size: 16-bit X PATH#1 volatile setting Z Reserved Y PATH#2 volatile setting U Reserved