Delta Electronics — P5.xxx Motion control parameters

Parameters ASDA-B3 8 Settings: In PR mode, if the motor rotates in the positive direction and its feedback position exceeds the value of P5.008, AL283 occurs. Settings: In PR mode, if the motor rotates in the negative direction and its feedback position exceeds the value of P5.009, AL285 occurs. Settings: Data size (N x 32 bits) means size N of data array. Settings: Specify the address in the data array when reading and writing data. Refer to Chapter 7 for detailed instructions. 8-110 Address: 0510H P5.008 Positive software limit 0511H Default: 2147483647 Control mode: Unit: PUU Setting range: Format: DEC Data size: Address: 0512H P5.009 Negative software limit 0513H Default:

-2147483648 Control mode: PR Unit: PUU Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit Address: 0514H P5.010★■ Data array - data size 0515H Default: - Control mode: All Unit: - Setting range: Read-only Format: DEC Data size: 16-bit Address: 0516H P5.011■ Data array - address for reading and writing 0517H Default: 0 Control mode: All Unit: - Setting range: 0 to (value set by P5.010 minus 1) Format: DEC Data size: 16-bit