ASDA-B3 Parameters Y: axis source of Capture 0: Capture is not working 1: reserved 8 2: pulse command (CN1) 3: motor encoder (CN2) Note: when the source of Compare is the Capture axis, the source of Capture (P5.039.Y) cannot be changed. Z: trigger logic 0: NO (normally open) 1: NC (normally closed) U: trigger minimum interval (unit: ms) Note: refer to Chapter 7 for detailed instructions for Capture. Settings: The first delay time of PR mode. Settings: The second delay time of PR mode. Settings: The third delay time of PR mode. 8-117 Address: 0550H P5.040 Delay time after position reached (Number #0) 0551H Default: 0 Control mode: PR Unit: ms Setting range: 0 to 32767 Format:
DEC Data size: 16-bit Address: 0552H P5.041 Delay time after position reached (Number #1) 0553H Default: 100 Control mode: PR Unit: ms Setting range: 0 to 32767 Format: DEC Data size: 16-bit Address: 0554H P5.042 Delay time after position reached (Number #2) 0555H Default: 200 Control mode: PR Unit: ms Setting range: 0 to 32767 Format: DEC Data size: 16-bit Address: 0556H P5.043 Delay time after position reached (Number #3) 0557H Default: 400 Control mode: PR