Parameters ASDA-B3 8 Settings: Displays the axis position of Capture pulse source. Note that this parameter is only writable when Capture stops (refer to P5.039). If the axis source of Capture is the main encoder, this parameter is write-protected and the Capture axis position is the feedback position of the motor (monitoring variable 00h). Settings: When Capture stops, this parameter indicates the number of data expected to be captured (readable and writable). When Capture activates, this parameter indicates the remaining number of data to be captured (read-only); each time it captures one data, the value of P5.038 decrements by 1 until the value is 0, indicating that capturing is complete.
Note: the total number of data from Capture cannot exceed 100. Settings: Y Z U X X: Capture setting 8-116 Address: 054AH P5.037■ Capture-Axis position 054BH Default: 0 Control mode: All Unit: Pulse unit of capture source Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit Address: 054CH P5.038■ Capture-Number of capturing times 054DH Default: 1 Control mode: All Unit: - Setting range: 1 to (value set by P5.010 minus value set by P5.036) Format: DEC Data size: 16-bit Address: 054EH P5.039■ Capture-Activate CAP control 054FH Default: 0x2010 Control mode: All Unit: - Setting range: 0x0000 - 0xF13F Format: HEX Data size:
16-bit X Capture setting Z Trigger logic Y Axis source of Capture U Trigger minimum interval Bit Function Description 0 Activate Capture Start capturing; after finishing capturing, set to 0 1 Reset position After capturing the first data, reset the position coordinate of the first data. The reset coordinate position is set by P5.076 2 Reserved - 3 Execute PR Execute PR#50 after capturing is complete