Delta Electronics — P5.xxx Motion control parameters

ASDA-B3 Parameters 8 Settings: Second target speed of PR mode. Settings: Third target speed of PR mode. Settings: Fourth target speed of PR mode. 8-121 Address: 057AH P5.061 Target speed setting #1 057BH Operation Panel / software Communication PR Control mode: interface: Default: 50.0 500 Data size: 32-bit Unit: 1 rpm 0.1 rpm - - Setting range: 0.0 to 6000.0 0 to 60000 - - Format: DEC DEC - - Example: 15 = 15 rpm 150 = 15 rpm - - Address: 057CH P5.062 Target speed setting #2 057DH Operation Panel / software Communication PR Control mode: interface: Default: 100.0 1000 Data size: 32-bit Unit: 1 rpm 0.1 rpm - - Setting range: 0.0 to 6000.0 0 to 60000 - - Format: DEC DEC - - Example:

15 = 15 rpm 150 = 15 rpm - - Address: 057EH P5.063 Target speed setting #3 057FH Operation Panel / software Communication PR Control mode: interface: Default: 200.0 2000 Data size: 32-bit Unit: 1 rpm 0.1 rpm - - Setting range: 0.0 to 6000.0 0 to 60000 - - Format: DEC DEC - - Example: 15 = 15 rpm 150 = 15 rpm - -