Parameters ASDA-B3 8 Settings: Fifth target speed of PR mode. Settings: Sixth target speed of PR mode. Settings: Seventh target speed of PR mode. 8-122 Address: 0580H P5.064 Target speed setting #4 0581H Operation Panel / software Communication PR Control mode: interface: Default: 300.0 3000 Data size: 32-bit Unit: 1 rpm 0.1 rpm - - Setting range: 0.0 to 6000.0 0 to 60000 - - Format: DEC DEC - - Example: 15 = 15 rpm 150 = 15 rpm - - Address: 0582H P5.065 Target speed setting #5 0583H Operation Panel / software Communication PR Control mode: interface: Default: 500.0 5000 Data size: 32-bit Unit: 1 rpm 0.1 rpm - - Setting range: 0.0 to 6000.0 0 to 60000 - - Format: DEC DEC - - Example:

15 = 15 rpm 150 = 15 rpm - - Address: 0584H P5.066 Target speed setting #6 0585H Operation Panel / software Communication PR Control mode: interface: Default: 600.0 6000 Data size: 32-bit Unit: 1 rpm 0.1 rpm - - Setting range: 0.0 to 6000.0 0 to 60000 - - Format: DEC DEC - - Example: 15 = 15 rpm 150 = 15 rpm - -