Delta Electronics — P5.xxx Motion control parameters

ASDA-B3 Parameters 8 Settings: Before executing the macro command, set the relevant parameters in advance. The function of the parameter is determined by the macro command. Not every macro command requires this parameter. Settings: Write to this parameter to issue a macro command; read this parameter to examine the execution result of a macro command. If the command 0x0003 is issued, 0x1003 is returned if successful; and 0xF03X if unsuccessful (depending on the command description). If you execute a command that is not supported, the failure code 0xF001 is returned. The command codes are listed in the following tables: 8-127 Address: 05C0H P5.096 Motion control macro command:

command parameter #1 05C1H Default: 0 Control mode: All Unit: - Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit Motion control macro command: issue command / Address: 05C2H P5.097■ execution result 05C3H Default: 0 Control mode: All Unit: - Setting range: 0 - 0x099F Format: HEX Data size: 16-bit Command code 0x0003 Parameter and data array protection: password setting, protection activation This function can only be executed prior to activating the parameter protection function. When the protection function is activated, the failure code is returned if this function is executed repeatedly. Macro parameters P5.093 = parameter groups 5, 6, and 7 are write-protected 0:

no protection 1: enable protection P5.094 = read protection range of parameter and data array (-1 to 7) -1: parameter groups 5, 6, 7 and data array are readable 0: parameter groups 5, 6, 7 and data array are unreadable 1: parameter groups 5, 6, 7 and data array #100 - 799 are unreadable 2: parameter groups 5, 6, 7 and data array #200 - 799 are unreadable 3: parameter groups 5, 6, 7 and data array #300 - 799 are unreadable 4: parameter groups 5, 6, 7 and data array #400 - 799 are unreadable 5: parameter groups 5, 6, 7 and data array #500 - 799 are unreadable 6: parameter groups 5, 6, 7 and data array #600 - 799 are unreadable 7:

parameter groups 5, 6, 7 are unreadable, but data array is readable P5.095 = set new password (1 to 16777215) P5.096 = confirm new password (1 to 16777215) Read the return value of P5.097 after executing the macro Success code 0x1003 Failure code 0xF031: protection function is activated and cannot be set repeatedly 0xF032: wrong password setting, P5.095 does not equal P5.096 0xF033: password value exceeds the allowable range (1 to 16777215) 0xF034: protection range P5.094 exceeds the allowable range (-1 to 7) 0xF035: protection level P5.093 exceeds the allowable range (0 to 1)