Parameters ASDA-B3 If returning to the origin is needed, set PATH to a non-zero value and set PABS = ORG_DEF. Example: 8 Upon completion of P6.000 = 0x0001, automatically execute Path#1. Set from absolute position (ABS) to 0 as the route of Path#1 (set P6.002 & P6.003). 2. If the origin is found (sensor or Z), and you want the motor to move an offset S and define the coordinate as P after moving, then PATH = non-zero and set ORG_DEF = P - S, and this absolute Position command = P. Settings: Origin definition. Settings: Format of this parameter: (High word h) DCBA : (Low word L) UZYX Definitions are as follows: YX TYPE, Path type:
when executing 1 - 3, it can be interrupted and stopped by DI.STP and software limits. 8-132 Address: 0602H P6.001 Origin definition 0603H Default: 0 Control mode: PR Unit: - Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit Address: 0604H P6.002 PATH#1 definition 0605H Default: 0x00000000 Control mode: PR Unit: - Setting range: 0x00000000 - 0xFFFFFFFF Format: HEX Data size: 32-bit High bit Low bit D C B A U Z Y X A SPD, Target speed index* X TYPE, Path type B DLY, Delay time index Y OPT, Option C AUTO*1 Z ACC, Acceleration time index* D Reserved U DEC, Deceleration time index* Y: OPT, Option X: TYPE, Path type Bit 3 Bit 2 Bit 1 Bit 0 - UNIT AUTO INS 1:
SPEED, constant speed control. 2: SINGLE, positioning control. It stops when finished. CMD OVLP INS 3: AUTO, positioning control. It automatically loads the next path when finished. - - - INS 7: JUMP, jump to the specified path. - ROM AUTO INS 8: write specified parameter to specified path. DIR OVLP INS A: indexing position control.