ASDA-B3 Parameters INS: executing this path interrupts the previous path. OVLP: allow overlapping of the next path. Overlapping is not allowed in Speed mode. When overlapping in Position mode, DLY has no function. 8 AUTO: once current PR path is finished, automatically load the next path. CMD: refer to Section 7.1.3 Motion control commands. UZ A: SPD, target speed index B: DLY, delay time index 8-133 U: DEC, Deceleration Z:
ACC, Acceleration time Corresponding Default value (ms) time index index parameter 0 0 P5.020 200 1 1 P5.021 300 2 2 P5.022 500 3 3 P5.023 600 4 4 P5.024 800 5 5 P5.025 900 6 6 P5.026 1000 7 7 P5.027 1200 8 8 P5.028 1500 9 9 P5.029 2000 10 10 P5.030 2500 11 11 P5.031 3000 12 12 P5.032 5000 13 13 P5.033 8000 14 14 P5.034 50 15 15 P5.035 30 A Corresponding parameter Default value (ms) 0 P5.060 20 1 P5.061 50 2 P5.062 100 3 P5.063 200 4 P5.064 300 5 P5.065 500 6 P5.066 600 7 P5.067 800 8 P5.068 1000 9 P5.069 1300 10 P5.070 1500 11 P5.071 1800 12 P5.072 2000 13 P5.073 2300 14 P5.074 2500 15 P5.075 3000 B Corresponding parameter Default value (ms) 0 P5.040 0 1 P5.041 100 2 P5.042 200