Delta Electronics — P6.xxx PR parameters

Parameters ASDA-B3 8  C: AUTO: once current PR path is finished, automatically load the next path. This function is only enabled when X = A indexing position control. Description of each bit: Note: the parameter format definition [C, A, U, Z] is different from the above table when the path type is [7]: write the specified parameter to the specified path. Refer to Chapter 7 for detailed instructions. Settings: P6.002 defines the property of the target point; P6.003 defines the target position of P6.002 or the target path for the Jump command. Settings: Refer to the description of P6.002.

8-134 3 P5.043 400 4 P5.044 500 5 P5.045 800 6 P5.046 1000 7 P5.047 1500 8 P5.048 2000 9 P5.049 2500 10 P5.050 3000 11 P5.051 3500 12 P5.052 4000 13 P5.053 4500 14 P5.054 5000 15 P5.055 5500 Bit Function Description Bit 0 - Bit 1 Reserved - Bit 2 AUTO 0: disable auto function 1: once current PR path is finished, automatically load the next path Address: 0606H P6.003 PATH#1 data 0607H Default: 0 Control mode: PR Unit: - Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit Address: 0608H P6.004 PATH#2 definition 0609H Default: 0x00000000 Control mode: PR Unit: - Setting range: 0x00000000 - 0xFFFFFFFF Format: HEX Data size: 32-bit