Delta Electronics — Table 8.1 Digital input (DI) descriptions

Parameters ASDA-B3 Table 8.1 Digital input (DI) descriptions 8 8-174 Value: 0x01 Triggering Control DI name Description method mode SON When this DI is on, servo is activated (Servo On). Level triggered All Value: 0x02 Triggering Control DI name Description method mode ARST After the alarm is cleared, the drive shows that the alarm is cleared when this DI is on. Rising-edge triggered All Value: 0x03 Triggering Control DI name Description method mode GAINUP In Speed and Position modes, when this DI is on (P2.027 set to 1), the gain switches to the original gain multiplied by the switching rate. Level triggered PT, PR, S Value:

0x04 Triggering Control DI name Description method mode CCLR Clear pulse counter and P2.050. Set DI.CCLR to 0 to clear position pulse deviation (applicable to PT mode). When this DI is on, the accumulative pulse deviation of the drive is cleared to 0. Rising-edge triggered, level triggered PT, PR Value: 0x05 Triggering Control DI name Description method mode ZCLAMP When the speed is slower than the setting of zero speed (P1.038), the motor stops operating when this DI is on. Speed command Set value of P1.038 (zero speed) ZCLAMP Input signal OFF ON Motor speed Set value of P1.038 (zero speed) Time Level triggered S ON Value:

0x06 Triggering Control DI name Description method mode CMDINV In Speed and Torque modes, the input command is reversed when this DI is on. Level triggered S, Sz, T