Delta Electronics — Table 8.1 Digital input (DI) descriptions

ASDA-B3 Parameters 8 8-175 Value: 0x08 Triggering Control DI name Description method mode In PR mode, after you select the PR command (POS0 - 6), the motor operates according to the command issued by the register when this DI is on. Rising-edge triggered Value: 0x09 Triggering Control DI name Description method mode In Speed and Position modes, motor torque is limited when this DI is on, and source of the limited Torque command is the internal register or analog voltage. Level triggered Value: 0x0C Triggering Control DI name Description method mode VPL Latch function of analog Position command. If this DI is on, position of the motor is held at the current position when the DI is triggered.

During the time this DI is on, the motor does not operate even when there is a change in the analog command. When this DI is off, the motor completes the command that was changed during the time the DI was on. Motor position (Turn) When DI is off, motor operates to the corresponding position inputted by analog Motor position when DI is triggered Analog input When DI is on, command (V) Voltage analog input when DI is command triggered changes the amount; motor does not move Level triggered PT