Delta Electronics — Table 8.1 Digital input (DI) descriptions

Parameters ASDA-B3 8 8-176 Value: 0x0D Triggering Control DI name Description method mode VPRS Clear function of analog Position command. If this DI is on, the position of the motor is held at the current position when DI is triggered. Despite the change in the analog command during the time DI is on, the motor remains at the current position even when the DI is off. However, the position that the motor remains at corresponds to the new analog command. Thus, the analog input command redefines the coordinate system of the motor.

Motor Position (Turn) Motor position when DI is When DI is on, all triggered input commands are cleared Analog input Voltage when DI command (V) is triggered Analog input When DI is off, motor command (V) does not move, but the zero point of the coordinate is redefined Level triggered PT Value: 0x10 Triggering Control DI name Description method mode SPDLM In Torque mode, motor speed is limited when this DI is on, and source of the limited Speed command is the internal register or analog voltage. Level triggered T Value:

0x11, 0x12, 0x13, 0x1A, 0x1B, 0x1C, 0x1E Triggering Control DI name Description method mode POS0 POS1 POS2 POS3 POS4 POS5 POS6 PR command selection (0 - 99) Level triggered PR Position CMD POS 6 POS 5 POS 4 POS 3 POS 2 POS 1 POS 0 CTRG Corres- ponding para- meter Homing 0 0 0 0 0 0 0 P6.000 P6.001 PR#1 0 0 0 0 0 0 1 P6.002 P6.003 … … PR#50 0 1 1 0 0 1 0 P6.098 P6.099 PR#51 0 1 1 0 0 1 1 P7.000 P7.001 … … PR#99 1 1 0 0 0 1 1 P7.098 P7.099