Delta Electronics — Table 8.1 Digital input (DI) descriptions

Parameters ASDA-B3 8 Note: the input function is disabled when P2.010 - P2.017 and P2.036 - P2.040 are set to 0. 8-180 Value: 0x43, 0x44 Triggering Control DI name Description method mode GNUM0 GNUM1 E-Gear ratio (numerator) selection 0 E-Gear ratio (numerator) selection 1 GNUM0, GNUM1 1st numerator (P1.044) Position 2nd numerator (P2.060) command 3rd numerator (P2.061) moving filter Pulse 4th numerator (P2.062) (P1.068) ---------------------------- Denominator (P1.045) Smooth filter (P1.008) Pulse Error Feedback pulse Level triggered PT Value: 0x45 Triggering Control DI name Description method mode INHP In Position mode, the external pulse input command has no function when this DI is on.

Note: this function has to be set to DI4 to ensure immediate pulse inhibition. Level triggered PT Value: 0x46 Triggering Control DI name Description method mode STP Motor stops. Rising-edge triggered PR Value: 0x47 Triggering Control DI name Description method mode PFQS Use this DI to set the emergency stop for deceleration time. The value for deceleration time is same as P5.003. If this DI is triggered, AL35F occurs and the motor starts decelerating. When the speed reaches 0, AL3CF occurs and servo is switched to Servo Off. Reset the alarm to switch the drive to the Servo On state. Rising-edge triggered PT, PR, T, S