ASDA-B3 Parameters 8 8-179 Value: 0x2B Triggering Control DI name Description method mode Use this DI to select the command source in PT-PR dual mode or PT-PR-S multiple mode. If this DI is off, it is in PT mode; if this DI is on, it is in PR mode. Level triggered Value: 0x37 Triggering Control DI name Description method mode JOGU When this DI is on, motor jogs in the positive direction. Level triggered All Value: 0x38 Triggering Control DI name Description method mode JOGD When this DI is on, motor jogs in the negative direction. Level triggered All Value: 0x39 Triggering Control DI name Description method mode EV1 Event trigger command #1. Refer to the setting of P5.098 and P5.099.
Rising- and falling-edge triggered PR Value: 0x3A Triggering Control DI name Description method mode EV2 Event trigger command #2. Refer to the setting of P5.098 and P5.099. Rising- and falling-edge triggered PR Value: 0x3B Triggering Control DO name Description method mode EV3 Event trigger command #3. Refer to the setting of P5.098 and P5.099. Rising- and falling-edge triggered PR Value: 0x3C Triggering Control DI name Description method mode EV4 Event trigger command #4. Refer to the setting of P5.098 and P5.099. Rising- and falling-edge triggered PR