Delta Electronics — Table 8.2 Digital output (DO) descriptions

Parameters ASDA-B3 8 8-182 Value: 0x07 Triggering Control DO name Description method mode ALRM When an alarm occurs, this DO is on. (Except for positive / negative limit, communication error, undervoltage, and fan error.) Level triggered All Value: 0x08 Triggering Control DO name Description method mode BRKR When the magnetic brake control signal is detected, adjust the settings of P1.042 and P1.043. ON OFF OFF SON ON [1*] [2*] OFF BRKR Motor Speed (P1.042) (P1.043) (P1.038) [2*] ZSPD [1*] Level triggered All Value: 0x09 Triggering Control DO name Description method mode HOME When homing is complete, it means the position coordinate system and position counter are defined and this DO is on.

When power is applied, this DO is off; when homing is complete, this DO is on. During operation, this DO is on until the position counter overflows (including commands or feedback). Then, this DO turns off. When the homing command is triggered, this DO is off; after homing is complete, this DO is on. Level triggered PR Value: 0x0D Triggering Control DO name Description method mode ABSW When there are absolute encoder alarms, this DO is on. - All Value: 0x0E Triggering Control DO name Description method mode IDXD Indexing coordinate is defined. When homing is complete, indexing coordinate is defined as well. - PR Value:

0x10 Triggering Control DO name Description method mode OLW This DO is on when the overload level setting is reached. tOL = Overload allowable time of the servo x value for the overload warning level (P1.056). When the overload accumulative time exceeds tOL, it sends the overload pre-warning (OLW). However, if the overload accumulative time exceeds the overload allowable time of the servo, it sends the overload error (ALRM). For example: the value for the overload warning level is 60%. (P1.056 = 60) When the output average load of the servo drive is 200% and the Level triggered All