ASDA-B3 Parameters 8 8-183 Value: 0x10 Triggering Control DO name Description method mode output time exceeds 8 seconds, the overload alarm (AL006) occurs. tOL = Duration when the output average load of the servo is 200% x value for the overload warning level = 8 sec x 60% = 4.8 sec Result: when the output average load of the servo drive is 200% for over tOL = 4.8 seconds, this overload warning DO is on (DO: 0x10). If the duration exceeds 8 seconds, then the overload alarm (AL006) occurs and sends the overload error (ALRM). Value: 0x11 Triggering Control DO name Description method mode WARN Warning outputs (positive / negative limit, communication error, undervoltage, and fan error).
Level triggered All Value: 0x12 Triggering Control DO name Description method mode OVF Position command / feedback overflows. Level triggered PT, PR Value: 0x13 Triggering Control DO name Description method mode SNL (SCWL) Software limit (negative limit). Level triggered PR Value: 0x14 Triggering Control DO name Description method mode SPL (SCCWL) Software limit (positive limit). Level triggered PR Value: 0x15 Triggering Control DO name Description method mode Cmd OK _ When the Position command is executing, this DO is off; after the command completes, this DO is on. This DO only indicates that the command is complete, but the motor positioning may not be complete yet. Refer to DO.TPOS.
Level triggered PR Value: 0x16 Triggering Control DO name Description method mode CAP OK _ Capture procedure is complete. Level triggered All Value: 0x17 Triggering Control DO name Description method mode MC OK _ When DO.Cmd OK and DO.TPOS are both on, then this DO is on. _ Refer to P1.048. Level triggered PR