Delta Electronics — 9.3 MODBUS communication protocol

MODBUS Communication ASDA-B3 RTU mode: Every data frame consists of 8-bit hexadecimal characters, which is more efficient than ASCII 9 mode for data transmission because it can be done without code interchange. For instance, when transmitting “64H” between the master and slave, just send “64H”. Characters are encoded into the following frames and transmitted in series. The method for checking each type of frame is as follows.

10-bit character frame (for 7-bit character) L H H 7N2 7E1 L H 7O1 L H 11-bit character frame (for 8-bit character) 8N2 L H L H 8E1 L H 8O1 9-4 Start bit 0 1 2 3 4 5 6 Stop bit Stop bit 7-data bits 10-bit character frame Start bit 0 1 2 3 4 5 6 Even Parity Stop bit 7-data bits 10-bit character frame Start bit 0 1 2 3 4 5 6 Odd Parity Stop bit 7-data bits 10-bit character frame Start bit 0 1 2 3 4 5 6 7 Stop bit Stop bit 8-data bits 11-bit character frame Start bit 0 1 2 3 4 5 6 7 Even parity Stop bit 8-data bits 11-bit character frame Start bit 0 1 2 3 4 5 6 7 Odd parity Stop bit 8-data bits 11-bit character frame