Delta Electronics — 11.2.2 Communication objects

CANopen Mode ASDA-B3 11.2.2 Communication objects The default of the Delta servo drive complies with the DS301 protocol. All CANopen data contains 11 an 11-bit identifier, generally referred to as "COB-ID". The COB-ID data format is as follows: Bit The following table lists the supported objects and the corresponding COB-IDs: 0 indicates the bit is off; 1 indicates the bit is on; X indicates the bit is set according to the requirement.

Communication dictionary 11-6 10 9 8 7 6 5 4 3 2 1 0 Bit Function Description Bit 6 - Bit 0 Node-ID Bit 10 - Bit 7 Function code Communication Function code Node ID Bit 6 5 4 32 1 0 COB-ID Object object Bit10 9 8 7 DEC (HEX) parameter NMT service 0 0 0 0 0 0 0 0 0 0 0 0 (0h) - SYNC object 0 0 0 1 0 0 0 0 0 0 0 128 (80h) 1005h - 1007h EMCY object 0 0 0 1 X X X X X X X 128 (80h) 1014h T PDO1 _ 0 0 1 1 X X X X X X X 384 (180h) + Node-ID 1800h R PDO1 _ 0 1 0 0 X X X X X X X 512 (200h) + Node-ID 1400h T PDO2 _ 0 1 0 1 X X X X X X X 640 (280h) + Node-ID 1801h R PDO2 _ 0 1 1 0 X X X X X X X 768 (300h) + Node-ID 1401h T PDO3 _ 0 1 1 1 X X X X X X X 896 (380h) + Node-ID 1802h R PDO3 _ 1 0 0 0 X X X X X X X 1024 (400h) + Node-ID 1402h T PDO4 _ 1 0 0 1 X X X X X X X 1152 (480h) + Node-ID 1803h R PDO4 _ 1 0 1 0 X X X X X X X 1280 (500h) + Node-ID 1403h T SDO _ 1 0 1 1 X X X X X X X 1408 (580h) + Node-ID 1200h R SDO _ 1 1 0 0 X X X X X X X 1536 (600h) + Node-ID 1200h NMT error control 1 1 1 0 X X X X X X X 1792 (700h) + Node-ID 1016h, 1017h 10 9 8 7 6 5 4 3 2 1 0 Communication object Object area 1000 - 1FFF Communication Profile Area 2000 - 2FFF Manufacturer Specific Profile Area 6000 - 9FFF Standardized Device Profile Area