Delta Electronics — 11.2.2.1 Process data object (PDO)

ASDA-B3 CANopen Mode 11.2.2.1 Process data object (PDO) Real-time data transmission can be achieved with Process data objects (PDOs). There are two types of PDOs: the sent TxPDO and the received RxPDO. This definition is from the perspective 11 of the servo drive, for example, the sent TxPDO refers to the object that the servo drive sends to the controller. Set the communication parameters and mapping parameters as shown in the following table to use the PDOs. The mapping parameter format of PDO is: Bit Bit Example: To set three PDOs (OD 6040h, OD 607Ah, and OD 6060h) in the first group of PDOs, the setting is as follows:

11-7 Received RxPDO Sent TxPDO Communication object Communication Mapping Communication object Communication Mapping object object object object parameter parameter parameter parameter R PDO1 _ 1400h 1600h T PDO1 _ 1800h 1A00h R PDO2 _ 1401h 1601h T PDO2 _ 1801h 1A01h R PDO3 _ 1402h 1602h T PDO3 _ 1802h 1A02h R PDO4 _ 1403h 1603h T PDO4 _ 1803h 1A03h 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Function Bit 0 - Bit 7 Object length Bit 8 - Bit 15 Object sub-index Bit 16 - Bit 31 Object index Mapping parameter Data Description setting for received PDO OD 1600 sub0 3 Set 3 PDO mappings.

OD 1600 sub1 6040h 00h 10h - OD 1600 sub2 607Ah 00h 20h - OD 1600 sub3 6060h 00h 08h - Note The total length is 38h (56-bit) which meets the specification of less than 64-bit.