Delta Electronics — 11.2.2.2 Service data object (SDO)

CANopen Mode ASDA-B3  Read data with SDO To use an SDO to read data with the controller, you need to write the request code and index 11 according to the SDO format. The servo drive then returns the object's data based on the object to be read. The following figure shows the packet format when the controller sends the SDO for reading data: COB-ID 600h+ Node-ID Packet (8 bytes in total) Controller Servo drive The following figure shows the packet format returned by the servo drive when the controller sends the SDO for reading data: COB-ID Packet (8 bytes in total) Controller Servo drive 580 h + Node-ID Note: for SDO abort codes, refer to Section 11.2.2.3.

11-10 0 1 2 3 4 5 6 7 Function Object index Object Data Description code sub-index Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 40h - - - Read data. 0 1 2 3 4 5 6 7 Function Object index Object Data Description code sub-index Byte 0 Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 43h - - - Data Read 4 bytes of data. 4Bh - - - Data Read 2 bytes of data. 4Fh - - - Data Read 1 byte of data. 80h - - - SDO abort codes Error code.