ASDA-B3 CANopen Mode 11.2.2.3 SDO abort codes The abort codes are as follows: 11 06020000h Object does not exist in the object dictionary. 06040041h Unable to map the object to the PDO. 06040042h The number and length of mapped objects exceed the PDO length. 06060000h Access failed due to hardware error (storage or restore error). 06070010h Data type does not match; parameter length does not match. 06090011h Sub-index does not exist. 06090030h The written parameter value is out of range. 08000000h General error. 080000a1h An error occurred when reading an object from EEPROM. 080000a2h An error occurred when writing an object to EEPROM. 080000a3h Invalid range when accessing EEPROM.
080000a4h EEPROM data content error occurred when accessing EEPROM. 080000a5h The entered password is incorrect when writing to the encryption area 08000020h Unable to transfer data or save data to the application. 08000021h Unable to transfer data or save data to the application due to restrictions (storage or restore in the wrong state). 08000022h Object is in use. 11-11 Abort code Description Client / server command is invalid or does not exist. Attempt to write a read-only object.