Delta Electronics — 11.2.2.4 Synchronization object (SYNC)

CANopen Mode ASDA-B3 11.2.2.4 Synchronization object (SYNC) The Synchronization objects (SYNCs) are periodically broadcast by the SYNC producer. 11 There is no data in the SYNC packet (L = 0). The SYNC protocol is as follows: SYNC producer (controller) Write SYNC SYNC consumer (servo drive) Request Indication Data size L = 0 Indication Indication The SYNC object is used to achieve PDO transmission and reception synchronization between the controller and servo drive. The SYNC object transmission cycle is set by the object OD 1006h (see Section 11.4 for detailed settings).

The following figure shows the timing sequence between the servo drive RxPDO reception and the controller SYNC transmission. The controller transmits RxPDO to the servo drive between two SYNCs (communication cycle), and the servo drive will not execute the RxPDO received in the previous communication cycle until it receives the SYNC. Communication cycle SYNC Message SYNC Message 11-12 Objects mapped Execute the synchronous mapped RxPDO received in the previous cycle in synchronous RxPDO Execute the synchronous mapped RxPDO received in the previous cycle in synchronous RxPDO