Delta Electronics — 11.2.2.5 Emergency object (EMCY)

ASDA-B3 CANopen Mode The following figure shows the timing sequence between the servo drive TxPDO transmission and the controller SYNC transmission. The servo drive transmits the TxPDO data to the 11.2.2.5 Emergency object (EMCY) When the servo detects an abnormality, it sends an alarm and notifies the controller with the Emergency object. The Emergency object can only transmit one alarm at a time. When a higher priority alarm occurs before the previous lower priority alarm is cleared, the higher priority alarm overwrites the previous alarm and notifies the controller as an Emergency object.

Controller Servo drive COB-ID 80 Packet (8 bytes in total) 11-13 11 Objects mapped in synchronous TxPDO Objects mapped in synchronous TxPDO 0 1 2 3 4 5 6 7 Error code Error register Servo alarm N/A Byte 0 Byte 1 Byte 2 Byte 3 Bytes 4 - 7 OD 1001h Refer to Chapter 12 for details.