CANopen Mode ASDA-B3 11.3.3 Homing Mode After homing is complete, the coordinate system of the servo drive is established and the drive 11 can start executing the position command issued by the controller. Delta servo drives offer 35 homing modes, including finding the home switch, positive and negative limits, and motor Z pulse.
[PUU] Homing speeds (6099h) Speed [RPM] Max profile velocity (607Fh) limit function Trajectory generator Max torque (6072h) Quick stop deceleration (6085h) Acceleration limit function Max acceleration (60C5h) Homing acceleration / deceleration (609Ah) [ms] Filter P1.008 P1.025 - Max deceleration (60C6h) E-Gear ratio 6093h sub1 6093h sub2 P1.028 P1.036 P1.068 Position control Speed control Torque control Servo motor loop loop loop Torque actual value (6077h) M Velocity actual value (606Ch) Encoder Operation steps: 1. Set OD 6060h to 06h to set the mode as Homing Mode. 2. Set OD 607Ch for the home offset. 3. Set OD 6098h for the method to find the origin point. 4.
Set OD 6099h sub1 for the speed when searching for the home switch. 5. Set OD 6099h sub2 for the speed when searching for the Z pulse. 6. Set OD 609Ah for the homing acceleration / deceleration time. 7. Set OD 6040h for the control command. Follow these steps. Steps 7.1 and 7.2 are to bring the servo drive's state machine into the ready state. For more details of the state machine, refer to Section 11.2.2.6. 11-24 Homing method (6098h) Homing function Home offset (607Ch) E-Gear ratio 6093h sub2 6093h sub1 Step Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Description 7.1 0 0 1 1 0 Shutdown. 7.2 0 0 1 1 1 Switch on (ready for servo on). 7.3 0 1 1 1 1 Enable operation (servo on).
7.4 1 1 1 1 1 Command triggered (rising-edge triggering).