Delta Electronics — 11.4.3.1 OD 1XXXh communication object group

ASDA-B3 CANopen Mode Format of this object: (High word h) DCBA : (Low word L) UZYX Error code Bit 0 - Bit 15 11 Definitions are as follows:  UZYX: error code. Refer to the error code definition in DS 402.  DCBA: Delta servo alarm. Refer to Chapter 12 Troubleshooting. Example: When you operate the servo, if the encoder cable is not correctly connected, the servo drive panel displays AL011 and its error code is stored in the 1003h array. The display is as follows: Byte: High word Low word AL011 is defined as encoder error based on the Delta servo alarm. Error code: 0x7305 is defined as an Incremental Sensor 1 fault according to DS 402. Object 1005h: COB-ID SYNC message Object function:

This object is read-only and cannot be set. 31 Bit 15 Bit 11-35 A Bit 16 - Bit 31 Delta servo alarm X B Y C Z D U Delta servo alarm (UINT16) Error code (UINT16) 0x0011 0x7305 Index 1005h Name COB-ID SYNC message Object code VAR Data type UNSIGNED32 Access RO PDO mapping No Setting range UNSIGNED32 Default 80 h 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Function Description Bit 31 - Bit 11 Reserved - Bit 10 - Bit 0 SYNC-COB-ID = 0x80 -