CANopen Mode ASDA-B3 Object 1006h: Communication cycle period 11 Object function: This object is to set the communication cycle (unit: μs). The communication cycle is the interval between two SYNCs. If you are not using SYNC, set this object to 0. Object 100Ch: Guard time Object function: The Life Guarding Protocol includes OD 100Ch and 100Dh. OD 100Ch is the guard time in milliseconds and OD 100Dh is the multiplying factor. Therefore, OD 100Ch multiplied by OD 100Dh gives the life time for the Life Guarding Protocol. If the time (OD 100Ch) is set to 0, then this setting is invalid. Example: if OD 100Ch = 5 ms and OD 100Dh = 10, then life time equals 50 ms. Object 100Dh:
Life time factor 11-36 Index 1006h Name Communication cycle period Object code VAR Data type UNSIGNED32 Access RW PDO mapping No Setting range UNSIGNED32 Default 0 Unit μs Index 100Ch Name Guard time Object code VAR Data type UNSIGNED16 Access RW PDO mapping No Setting range UNSIGNED16 Default 0 Unit ms Index 100Dh Name Life time factor Object code VAR Data type UNSIGNED8 Access RW PDO mapping No Setting range UNSIGNED8 Default 0