Delta Electronics — 3.1.1 Connecting to peripheral devices (connecting to Delta communication type servo motor)

Wiring ASDA-B3 Installation precautions: 1. Make sure the power and wiring connections of the R, S, T, and L 1C , L 2C are correct. Refer to 3 Appendix A Specifications for the correct voltage input to avoid any damage to the servo drive and dangerous operating conditions. 2. Make sure the UVW terminal block is correctly wired to avoid abnormal operation of the motor. 3. When installing an external regenerative resistor, P and D contacts are left open, and the external regenerative resistor is connected to P and C contacts. When using the built-in regenerative resistor, P and D contacts are short-circuited, and P and C contacts are left open. 4.

When an alarm occurs or the system is in the emergency stop status, use DO.ALRM or DO.WARN to disconnect the power at the magnetic contactor (MC) so as to power off the servo drive. 3-4