Delta Electronics — 11.4.3.1 OD 1XXXh communication object group

ASDA-B3 CANopen Mode Node ID and corresponding COB-ID 11 Object 1016h: Consumer heartbeat time Object function: Bit Bit Consumer heartbeat time is defined as the time the servo drive expects to receive a heartbeat. For the setting, consumer heartbeat time must be greater than the producer heartbeat time. Due to delays and other uncontrollable external factors in transmitting the heartbeat, you must retain a tolerance margin value. When the heartbeat consumer does not receive the heartbeat signal within the receiving time, the heartbeat event is triggered, meaning AL180 is triggered.

11-39 Node ID COB-ID 1 129 (81h) 2 130 (82h) ~ ~ 127 255 (FFh) Index 1016h Name Consumer heartbeat time Object code ARRAY Data type UNSIGNED32 Access RW PDO mapping No Sub-index 0 Description Number of sub-index Data type UNSIGNED8 Access RO PDO mapping No Setting range 1 Default 1 Sub-index 1 Description Consumer heartbeat time Data type UNSIGNED32 Access RW PDO mapping No Setting range UNSIGNED32 Default 0 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Function Description Bit 31 - Bit 24 Reserved - Bit 23 - Bit 16 Node-ID UNSIGNED8 Bit 15 - Bit 0 Heartbeat time UNSIGNED8; unit: ms