CANopen Mode ASDA-B3 11 Object function: Write 0x64616F6C (load) to sub-index 1 to reset all OD parameters to their default values. Object 1014h: COB-ID EMCY Object function: Bit Bit The emergency (EMCY) function is as follows:
11-38 Sub-index 0 Description Number of sub-index Data type UNSIGNED8 Access RO PDO mapping No Setting range UNSIGNED8 Default 1 Sub-index 1 Description Restore communication parameters Data type UNSIGNED32 Access RW PDO mapping No Setting range No Default 1 Index 1014h Name COB-ID emergency message Object code VAR Data type UNSIGNED32 Access RO PDO mapping No Setting range UNSIGNED32 Default 80h + Node-ID 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Function Description Bit 31 Emergency (EMCY) function 0: the emergency (EMCY) function is enabled (servo drive sends the EMCY command). 1:
the emergency (EMCY) function is disabled (servo drive does not send the EMCY command). Bit 30 - Bit 11 Reserved - Bit 10 - Bit 0 11-bit Identifier COB-ID 80h + Node-ID Communication Function code Node ID COB-ID Object parameter object index EMCY object 0001 1 - 127 129 (81h) - 255 (FFh) 1014h