Delta Electronics — 11.4.3.1 OD 1XXXh communication object group

ASDA-B3 CANopen Mode 11 Object function: This object includes the servo drive information. Object 1029h: Error behavior Object function: Generally, when the servo drive detects a serious fault in the Operational state, the state is automatically switched to the Pre-operational state. Use this object setting to switch the state to the Pre-operational state, maintain in the original state, or switch to the Stopped state.

11-41 Sub-index 3 Description Version Data type UNSIGNED32 Access RO PDO mapping No Setting range UNSIGNED32 Default N/A Index 1029h Name Error behavior Object code ARRAY Data type UNSIGNED8 Access RW PDO mapping No Sub-index 0 Description Number of error types Data type UNSIGNED8 Access RO PDO mapping No Setting range 1 Default 1 Sub-index 1 Description Communication error Data type UNSIGNED8 Access RW PDO mapping No Setting range UNSIGNED8 Default 0 OD 1029h sub1 setting Switch the state to 0 Pre-operational (only if current is operational) 1 Keep the original state 2 Stopped