CANopen Mode ASDA-B3 Object 1200h: Server SDO parameter 11 Object function: This object is read-only and cannot be set. Read the station number for transmitting and receiving the SDO with this object. Example: If the servo drive station number for receiving is 10: 600h + Node-ID:Ah = 60Ah => OD 1200 sub1 reads 60Ah. If the servo drive station number for transmitting is 10:
580h + Node-ID:Ah = 58Ah => OD 1200 sub2 reads 58Ah 。 11-42 Index 1200h Name Server SDO parameter Object code RECORD Data type SDO parameter Access RO PDO mapping No Sub-index 0 Description Number of sub-index Data type UNSIGNED8 Access RO PDO mapping No Setting range 2 Default 2 Sub-index 1 Description Controller sends to servo drive COB-ID Client->Server (rx) Data type UNSIGNED32 Access RO PDO mapping No Setting range UNSIGNED32 Default Index 1200h: 600h + Node-ID Sub-index 2 Description Servo drive returns to controller COB-ID Server->Client (tx) Data type UNSIGNED32 Access RO PDO mapping No Setting range UNSIGNED32 Default Index 1200h: 580h + Node-ID